17.01.2020

Fanuc Manuals

41

.GE Fanuc Automation Programmable Control Products Series 90®-30 Programmable Controller DeviceNet™ Modules GFK-2196 November 2002.Features may be described herein which are not present in all hardware and software systems. GE Fanuc Automation assumes no obligation of notice to holders of this document with respect to changes subsequently made.Operation of a Series 90-30 Slave (Server) DeviceNet Module.5-4 Fault Table Entries for a Series 90-30 DeviceNet Module.5-5 PLC Status References for a Series 90-30 DeviceNet Module. 5-6 Device Status Bits for the Series 90-30 DeviceNet Master Module. 5-7 Chapter 6 Programmed Communications.6-1 COMMREQs for the Series 90-30 DeviceNet Modules.Command Code 9: Reading Identification, Status, and Error Information. 6-8 Command Code 4: Getting the Status of a Network Device.

  1. Fanuc Robocut Operating Manuals

6-12 Command Code 5: Getting Status Information of a Series 90-30 DeviceNet Slave Module or the Server Function of a Master Module.6-14 Command Code 6: Getting Input Status from a Device.LED indications. Chapter 3: PLC Configuration for the DeviceNet Master, explains how to add a DeviceNet Master Module to the configuration of the Series 90-30 PLC. It also explains how to configure communications connections, the module, and the DeviceNet network.Both of these modules can be installed in any rack in the Series 90-30 PLC. Each module counts as a single node on the DeviceNet network. However, the server function of each module is easily configured for up to two DeviceNet I/O Messaging connections and for Explicit Messaging.Series 90-30 DeviceNet Master Module The Series 90-30 DeviceNet Master Module (IC693DNM200) allows a Series 90-30 CPU to send and receive data over a DeviceNet network. It can act as master for up to 63 slaves on the DeviceNet network.

Fanuc Manuals

It can also be configured to simultaneously function as a slave to another master on the bus.Requires CIMPLICITY Machine Edition Logic Developer PLC version 3.0 with Service Pack for DeviceNet, or later. Graphic style from victorian to new century pdf download. Not compatible with the VersaPro™, Control, or Logicmaster™ programming software. The Series 90-30 Hand-Held Programmer (IC693PRG300) cannot be used to configure this module. Series 90®-30 Programmable Controller DeviceNet™ Modules – November 2002.Series 90-30 DeviceNet Slave Module The Series 90-30 DeviceNet Slave Module (IC693DNS201) interfaces a Series 90-30 PLC to a DeviceNet bus that is controlled by another master device.

DeviceNet Slave Module Module NET POWER Status MOD STATUS LEDs NET STATUS.Requires CIMPLICITY Machine Edition Logic Developer PLC version 3.0 with Service Pack for DeviceNet, or later. Not compatible with the VersaPro™, Control, or Logicmaster™ programming software. The Series 90-30 Hand-Held Programmer (IC693PRG300) cannot be used to configure this module.

Fanuc Robocut Operating Manuals

Series 90®-30 Programmable Controller DeviceNet™ Modules – November 2002.The DeviceNet network has a linear structure. There is a main trunk line with drop lines routed to the networked devices. Power and signals are carried on the same network cable. A Series 90-30 DeviceNet module can be connected directly to the trunk cable or installed as an individual drop or as part of a daisy-chain drop.There are four basic types of I/O messages: Polled, Strobed, Cyclic, and Change-of-State (COS).